| Sign In | Join Free | My components-electronic.com |
|
Brand Name : Daruifuno
Model Number : ASP121E
Certification : CE, ISO
Place of Origin : China
MOQ : 1
Price : USD25-250
Payment Terms : T/T,Western Union,MoneyGram
Supply Ability : 10000 Sets per Month
Delivery Time : 3-10 work days
Packaging Details : Carton
Product Name : pH sensor
Measuring Range : 0~14pH
Zero (E0) pH : ±0.25pH
SLOP% : >95%
Working Pressure : 0-6Bar
Working Temp : 0~100℃
Temperature Unit : PT100, PT1000, NTC10K customized
Installation Dimension : PG13.5
Tail Lead : Integral or split
Wire : standard 5 meters
Application : pure water >5μS/cm
Daruifuno ASP121E analog pH Sensor:
Precision and Longevity
The ASP121E pH sensor is a versatile and durable choice, engineered for a wide measuring range of 0 to 14 pH. It utilizes a low-impedance cylindrical glass membrane to deliver fast and stable readings.
A key feature is its sophisticated Ag/AgCl reference system. This design incorporates a double salt bridge and a KCl gel electrolyte, significantly extending the sensor's lifespan and ensuring reliable performance in challenging environments where conventional single-junction electrodes often fail.
Built for Reliability and High Performance Constructed with durability in mind, the electrode features a resilient glass body and a distinctive dot-shaped ceramic junction (frit), offering excellent resistance to chemical corrosion.
Operating Parameters:
Standard Operation: The sensor operates continuously from 0∘C to 80∘C with pressures reaching 6 bar.
High-Temperature Capability: For brief periods (less than 60 minutes), it can endure temperatures up to 100∘C at pressures up to 3 bar.
Customizable High-Temperature Model: An optional version is available for continuous use up to 100∘C or short-term spikes (under 60 minutes) up to 135∘C. This enhanced model has demonstrated excellent endurance, successfully completing over 40 high-temperature cycles in clean water testing.
Key Technical Specifications
The ASP121E is built for exceptional accuracy, with technical specifications to back it up:
Sensitivity (Slope): Greater than 95%.Zero Point (E0): ±0.25 pH.
Temperature Compensation: Offers flexible integration with PT100, PT1000, or NTC10K sensors for precise readings across varying temperatures.
Optimal Flow Rate: Designed for sample flow rates between 0.001 m/s and 0.5 m/s.
Physical Specifications: Standard dimensions are 12 mm in diameter and 120 mm in length, with customization available.
Installation: Features a standard PG13.5 mounting thread for straightforward integration.
Wiring: Available with integral or split leads for flexible setup.
This electrode is highly recommended for pure water applications with conductivity greater than 5μS/cm, establishing it as a definitive choice for reliable and precise pH monitoring.

| Model | ASP120E | ASP121E | ASP122E | ASP123E | ASP124E |
| Measuring Object | PH | ||||
| Measuring Range | 0~14pH | ||||
| Indicator Electrode | low impedance cylindrical glass membrane | ||||
| Reference System | Ag/AgCl reference electrode, double salt bridge, KCl gel | ||||
| Electrode Material | Glass+Dot-shaped ceramic hole | Glass+Porous tetrafluoro ring | Glass+ceramic sand core | ||
| Working Pressure | Medium and low temp environment: max. 0~6bar High temp environment: 0~3bar | ||||
| Working Temp. | Medium and low temp. environment: 0~80℃, continuous work High temp. environment: 80~100℃, continuous work for less than 60 minutes
Customzied as below : Medium and low temp. Env.: 0~100℃, continuous work High temp. Env.: 100~135℃, continuous work < 60 mins High temp. Env. work more than 40 times (clean water test env.) | ||||
| Sample Flow Rate | 0.5 m/s ≥ flow velocity ≥ 0.001 m/s | ||||
| Zero (E0) | ±0.25pH | ||||
| SLOP% | >95% | ||||
| Temperature Unit | PT100, PT1000, NTC10K customized | ||||
| Dimension | Standard: diameter 12mm/Length 120mm (customized) | ||||
| Installation Thread | PG13.5 | ||||
| Tail Lead | Integral or split | ||||
| Application | Strong acid and alkali | Normal temp. pure water >5μS/cm | Harsh industrial process* | Normal temp. desulfurization or viscous slurry | Hydrofluoric acid with concentration ≤4000ppm |
| Model | ASP125E | ASP126E | ASP127E | ASR120E | ASP128E |
| Measuring Object | PH | ORP | PH | ||
| Measuring Range | 0~14pH | ±2000mV | 0~14pH | ||
| Indicator Electrode | low impedance cylindrical glass membrane | Platinum | glass membrane | ||
| Reference System | Ag/AgCl reference electrode, double salt bridge, KCl gel | ||||
| Electrode Material | Glass+ceramic sand core | ||||
| Working Pressure | Medium and low temp environment: max. 0~6bar High temp environment: 0~3bar | max. 0~6bar | |||
| Working Temp. | Medium and low temp. environment: 0~80℃, continuous work High temp. environment: 80~100℃, continuous work for less than 60 minutes
Customzied as below : Medium and low temp. Env.: 0~100℃, continuous work High temp. Env.: 100~135℃, continuous work < 60 mins High temp. Env. work more than 40 times (clean water test env.) | -15~80℃, continuous work | |||
| Sample Flow Rate | 0.5 m/s ≥ flow velocity ≥ 0.001 m/s | ||||
| Zero (E0) | ±0.25pH | ||||
| SLOP% | >95% | ||||
| Temperature Unit | PT100, PT1000, NTC10K customized | ||||
| Dimension | Standard: diameter 12mm/Length 120mm (customized) | ||||
| Installation Thread | PG13.5 | ||||
| Tail Lead | Integral or split | ||||
| Application | Strong acid and alkali | Harsh conditions &high pollution | Fermentation process | High temp. Industrial process | Low temp. |

The ASP121E glass pH sensor offers ultimate flexibility with custom mounting accessories for pure water environment:

The optional PTFE (Teflon) sheath. Featuring 3/4" NPT threads for easy attachment to mounting accessories, it ensures seamless integration across various applications.




|
|
Analog PH Electrode Suitable For Water Purification >5μS/Cm Images |