Brand Name : Daruifuno
Model Number : ASP121E
Certification : CE, ISO
Place of Origin : China
MOQ : 1
Price : USD25-250
Payment Terms : T/T,Western Union,MoneyGram
Supply Ability : 10000 Sets per Month
Delivery Time : 3-10 work days
Packaging Details : Carton
Product Name : pH sensor
Measuring Range : 0~14pH
Zero (E0) pH : ±0.25pH
SLOP% : >95%
Working Pressure : 0-6Bar
Working Temp : 0~100℃
Temperature Unit : PT100, PT1000, NTC10K customized
Installation Dimension : PG13.5
Tail Lead : Integral or split
Wire : standard 5 meters
Application : pure water >5μS/cm
This robust PH sensor ASP121E boasts a broad measuring range of 0 to 14 pH, making it highly versatile. It features a low-impedance cylindrical glass membrane for rapid and stable readings. The sophisticated Ag/AgCl reference system, with a double salt bridge and KCl gel, effectively and extends the sensor's lifespan, even where traditional single-junction electrodes might fail.
Engineered for Durability and Precision
The electrode is constructed from durable glass with a unique dot-shaped ceramic frit, offering superior resistance to chemical attack.
Operating Pressure & Temperature:
Standard Environments: Operates continuously from 0°C to 80°C with pressures up to 6 bar. For high-temperature applications, it can withstand up to 100°C for less than 60 minutes with pressures up to 3 bar.
Customizable High-Temp Version: Available for continuous use up to 100°C or short-term exposure up to 135°C (under 60 minutes). This model has been rigorously tested to endure more than 40 high-temperature cycles in a clean water environment.
Key Technical Specifications:
Slope Percentage: Greater than 95% for exceptional accuracy and sensitivity.
Zero Point (E0): ±0.25 pH.
Temperature Compensation: Highly customizable with options for PT100, PT1000, or NTC10K sensors to ensure precise pH readings across
varying temperatures.
Sample Flow Rate: Optimized for flow rates between 0.001 m/s and 0.5 m/s.
Dimensions: Standard dimensions are 12mm in diameter and 120mm in length, with customizable options available.
Installation: Features a standard PG13.5 mounting thread for simple integration into existing systems.
Leads: Integral or split leads provide flexible installation options to suit your needs.
This electrode is particularly well-suited for pure water >5μS/cm applications ,it is the definitive choice for reliable and accurate pH measurement.

| Model | ASP120E | ASP121E | ASP122E | ASP123E | ASP124E |
| Measuring Object | PH | ||||
| Measuring Range | 0~14pH | ||||
| Indicator Electrode | low impedance cylindrical glass membrane | ||||
| Reference System | Ag/AgCl reference electrode, double salt bridge, KCl gel | ||||
| Electrode Material | Glass+Dot-shaped ceramic hole | Glass+Porous tetrafluoro ring | Glass+ceramic sand core | ||
| Working Pressure | Medium and low temp environment: max. 0~6bar High temp environment: 0~3bar | ||||
| Working Temp. | Medium and low temp. environment: 0~80℃, continuous work High temp. environment: 80~100℃, continuous work for less than 60 minutes
Customzied as below : Medium and low temp. Env.: 0~100℃, continuous work High temp. Env.: 100~135℃, continuous work < 60 mins High temp. Env. work more than 40 times (clean water test env.) | ||||
| Sample Flow Rate | 0.5 m/s ≥ flow velocity ≥ 0.001 m/s | ||||
| Zero (E0) | ±0.25pH | ||||
| SLOP% | >95% | ||||
| Temperature Unit | PT100, PT1000, NTC10K customized | ||||
| Dimension | Standard: diameter 12mm/Length 120mm (customized) | ||||
| Installation Thread | PG13.5 | ||||
| Tail Lead | Integral or split | ||||
| Application | Strong acid and alkali | Normal temp. pure water >5μS/cm | Harsh industrial process* | Normal temp. desulfurization or viscous slurry | Hydrofluoric acid with concentration ≤4000ppm |
| Model | ASP125E | ASP126E | ASP127E | ASR120E | ASP128E |
| Measuring Object | PH | ORP | PH | ||
| Measuring Range | 0~14pH | ±2000mV | 0~14pH | ||
| Indicator Electrode | low impedance cylindrical glass membrane | Platinum | glass membrane | ||
| Reference System | Ag/AgCl reference electrode, double salt bridge, KCl gel | ||||
| Electrode Material | Glass+ceramic sand core | ||||
| Working Pressure | Medium and low temp environment: max. 0~6bar High temp environment: 0~3bar | max. 0~6bar | |||
| Working Temp. | Medium and low temp. environment: 0~80℃, continuous work High temp. environment: 80~100℃, continuous work for less than 60 minutes
Customzied as below : Medium and low temp. Env.: 0~100℃, continuous work High temp. Env.: 100~135℃, continuous work < 60 mins High temp. Env. work more than 40 times (clean water test env.) | -15~80℃, continuous work | |||
| Sample Flow Rate | 0.5 m/s ≥ flow velocity ≥ 0.001 m/s | ||||
| Zero (E0) | ±0.25pH | ||||
| SLOP% | >95% | ||||
| Temperature Unit | PT100, PT1000, NTC10K customized | ||||
| Dimension | Standard: diameter 12mm/Length 120mm (customized) | ||||
| Installation Thread | PG13.5 | ||||
| Tail Lead | Integral or split | ||||
| Application | Strong acid and alkali | Harsh conditions &high pollution | Fermentation process | High temp. Industrial process | Low temp. |

The ASP121E glass pH sensor offers ultimate flexibility with custom mounting accessories for pure water environment:
The optional PTFE (Teflon) sheath. Featuring 3/4" NPT threads for easy attachment to mounting accessories, it ensures seamless integration across various applications.




|
|
High Temperature Resistant 135℃ Analog PH Electrode For Pure Water >5μS/Cm Images |